外文翻译
三江学院
毕业设计(论文)外文资料翻译
院系
电气
专 业
电气工程及其自动化
学生姓名
王吉书
班级学号
B08071118
外文出处
附件:
1.外文资料翻译译文(约3000汉字);
2.外文资料原文(与课题相关的1万印刷符号左右)。
附件1
英文文献
Substationsystemover-voltageprotectiontechnology
Secondsubstationequipmentover-voltageprotectiononelectronicinformationsystemfortheprotectionofcoreequipmentfortheconstructionofaprotectedbothpressureandotherpotentialsystem,andthroughalllevelsofover-voltagesurgeprotectorsofthecurrentstepbystepintothelandofChina,Substationsecondarysafetyequipmentandreliableoperation.
1secondover-voltagesubstationprotection
Inrecentyears,thesubstationcommunications,communicationssystems,protectionsystems,backgroundmanagementmodulefrequentover-voltagedamage,themainreasonforthisisweakanditsrelatedsystemsproductsover-voltageprotectionlevelisweak,ornoguardagainstover-voltageTechnicalmeasures,theconsequencesforthesafeoperationofpowergridsbringaboutagreaternegativeimpact.Withintegratedautomationsystemsandautomationsystemssuchascommunicationsystemsinthesubstationweaksecondarybythewideruseofsuchelectronicsystems(equipment)componentsoftheintegratedmoreandmore,thegrowingvolumeofinformationstorage,speedandaccuracyoftheIncreasedandoperatesonlyafewvolts,currentinformationonlymicroamplevel,thusextremelysensitivetooutsideinterference,especiallythelightningandelectromagneticpulse,suchasover-voltagetoleranceislow.Whenthunderandlightning,suchasover-voltageandaccompaniedbytheelectromagneticfieldsreachacertainthreshold,rangingfromsystemfailurecaused,resultedinheavyequipmentorpermanentdamagetoitscomponents.Despitethethunderandlightningviewpointofelectronicsystems(equipment)isunlikely,butlightningstrikeneartheland,buildings,communicationandairsupplylinedirectlyLeiyundischargeform,orbecauseofelectrostaticinductionandtheimpactofelectromagneticinductionformationofover-voltage,Theremightbeconnectedtothepowerlines,signallinesorgroundingsystem,throughvariousinterfacestotransfer,coupling,radiationandotherformsofinvasiveelectronicsystem(equipment)andleadtoseriousdisturbancesorincidents.Therefore,strengtheningandimprovingtheelectronicsystem(equipment)protection,tominimizetheimpactofinterferencebylightningandotherdamagecauseddirectlossesandindirectlosses,hasbecometheurgentneedtosolvetheproblem.
2over-voltageprotectiondesign
IEC(InternationalElectrotechnicalCommission)TC/81minetechnicalcommitteewillbedividedintointernalandexternalminemineintwoparts,theexternalmineislightningrod(orwithlightning,lightningnetwork),YinXiaxianandgroundingsystem,Objectstobeprotectedfromdirectlightningstrikes,mineistopreventinternallightningandotherinternalover-voltagedamagecausedbyinvasiveequipment.Acomprehensivemineandover-voltageprotectionsystemsmustbeintegrateduseofdischarge(segregation),bothpressure(andotherpotential),shielding(isolation),grounded,limitpressure(clamp)protection,andothertechnology,inaccordancewiththeexternalmineAndtheprincipleofinternalmine,inaccordancewiththetargetsofprotectivefeatures,flexibleapplicationtotakeconcretemeasures,constituteacompleteprotectionsystem.Over-voltagesubstationintheformare:
Lightningover-voltage,theresonantfrequencyover-voltageandover-voltage,over-voltageoperation,theseover-voltagetransmissionorelectromagneticinductiontothewaythelinesandequipmentonadangerousover-voltage,inparticular,Lightningover-voltage,lightningsubstation,inthelow-voltagepowersupplysystemandweaksystemtoproduceastrongover-voltagesensor,whilethesubstationtopotentialrise(forexample:
thesubstationgroundingresistanceto1Q,lightningcurrent10kA,whilethepotentialfor10kV),duetotheincreasedpotentialofthecounterlinesandequipmentdamagedlinesandequipmentandtheeventshaveoccurred,therefore,despitethesubstationoutsidetheminesystem(lightningrod.YinXiaxianAndgroundingdevices)inlinewithnationalstandardsandtherequirementsofBuban,andtheintegratedautomationandcommunicationsautomationsystems,suchasweaksecondaryhavebeentaken,suchasshielding,grounding,isolation,filtering,andothermeasures,butitcannotcompletelyavoidover-voltagepowerfullightningAndvoltageofthesystemcounterthedisruptioncauseddamageand,therefore,thesecondweaksystemsubstationandamine-voltagemustalsotaketheappropriateprotectivemeasures,inaccordancewiththeIECwithinthemineareaEMP,thedevice'spowercord,signalLines,datalines,andtheinstallationoflightningprotectionandinternalover-voltagedevicestopreventlightningsensors,channelingpeoplealongthelightningcurrent,voltagecounterattack,suchastransientvoltagesurgetootransientover-voltagecausedbyafaultanddamagedelectronicequipment.Over-voltagesurgeprotectioninaccordancewithitsconnectionmodeisdividedintotwoseriesandparallel,theuseofover-voltagesurgeprotectiontandemwith,theremayexistbecauseofsignaltransmissiondoesnotmatchthecausesoftransmissionofthesignalinterference,inparticulardataCommunicationInterfaceintheserieswereover-voltagesurgeprotectioninplace,willhavethenormaldatacommunications.Therefore,thedatacommunicationsaccessI:
Iintheserieswereover-voltagesurgeprotectioninplace,thetransmissionofdatamustbecarriedoutconscientiouslycheckifthedataarenotnormaltransmission,itmaybeduetothereasonsdonotmatchthetransmissionsignalInterference,shouldbereplacedtomatchtheover-voltagesurgeprotectionfor.Iftheuseofover-voltagesurgeprotectionforuseofparallel,thesituationisbasicallynon-existent,buttheconnectionmodeofover-voltagesurgeprotectionforhighertechnicalrequirements.
3secondarysystemover-voltagesubstationprotection
3.1pointsover-voltageelectricitysystemprotection
SubstationinstalledinthecommunicationsdispatchautomationsystemsareusedACpoweroraDCpowersupplyequipmentfortherectificationofitslinksaregenerallylargercapacityfiltercapacitance,thetransientover-voltageshockabsorptionofacertainextent,thestationLow-voltagetransformersidegotofeedbetweenthescreenusingashieldedcableandequipmenthaveagoodgrounding,theuseofmoderntechnologytoanalyzemine,wemustincreasethecircuit'ssegregationmeasures,becauseitsgrounding,protectionandotherelectricalgroundingallGroundingdevicesusingthesameequipment,andequipmentareinaLPZOB,therelativestrengthofstrongelectromagneticpulse,thestationchangedtopreventlow-pressuresidealthoughtherearelinesintrusivewavearrester,buttheresidualpressurehigh,inthesubstationoflightning,throughthelineCouplingandthepotentialrisecausedbyover-voltagecounterattackstillexist,andhigh-pressuresideoftheresidualpressureashighasseveralthousandvolts,itisnecessarytotheseschedulingautomationequipmentforthepowersupplyover-voltagecircuitprotection.LightningProtectioninaccordancewiththeprincipleofregionaldivision,substationequipmentinthesecondarypowersupplysystemover-voltagesensorslightningprotectionmaybetwo(B,Clevel)fortheprotectionofsegregation.B-mineuseisgenerallygreaterflowcapacityofthemineinstallations,theLightningcouldbemorecasualLiuxiepeople,toachievetheobjectiveofcurrentlimit,over-voltageatthesametimewillreducetoacertainextent,c-mineuseWithlowerresidualpressureofthemineinstallations,youcanloopintheremainingscatteredlightningLiuxiepeople,tolimitthepurposeofover-voltage,over-voltageequipmentcanbereducedtotheleveloftolerance.Themainpowersupplysystemisinhibitedlightningprotectionandoperationofthepowerbacktotheroadandover-voltagesurge.Accordingtothesubstationstatusofthesubstationofthesecondmine-sensingsystemandtheoperationanduseoftwoover-voltageprotection.Asbuildmoresubstationsintheregionmoreopen,relativelystrongelectromagneticstrength,powerlinesandcommunicationcablesareveryvulnerabletolightningattackssensors,sensorsalongtheover-voltagepowerlinesandcommunicationlinesintoonedevice,whichwilldamageequipment,Therefore,theexchangeoffirst-classbustoinstallthepowerprotection(Blevel)istoensurethesafetyoftheentirecontrolroom,and80percentoftheover-voltageChina,scatteredtotheearth,playaprimaryroleintheprotection,butarestillintheexchangeoffeederSomeoftheB-levelpowersupplyvoltageandminetheresidualpressureincreaseson-lineandmustthereforebeimportantintheexchangeoffeederlines(DCchargingscreen,UPS,etc.)c-levelpowerprotection,whichwouldcurbover-voltageelectricalequipmenttoback-endTotheleveloftolerance.
Protectivelocation:
Itis1EC1312(LEMPprotection"intheregionoflightningprotectionprinciples.Arresterinstallationshouldbeindifferentlocationsatthejunctionofprotectedareas,thisnetwork,thefirst-classprotectionshouldbelocatedinthebusexchange.InTwoonthebuswiththeinstallationofaB-classmodelsofathree-phasepowersupplyvoltagesurgeprotector.
InstallLocation:
ACbus(cabinet).
3.1.2second-classprotectionmeasurestodealwith
Forthemoreimportantfeederlinesontheexchangeofequipment,herefortheDCchargescreen,theinstallationofc-levelthree-phasepowerarrester.AsDCchargingscreenistwo-wayexchangeofelectricitys