1
(文档含英文原文和中文翻译)
中英文对照外文翻译文献
BiologicaleffectsoftheMagneticStimulationontheToadHeart
Abstract-Westimulatedtheexposedtoadheartbyalowfrequencyandhighenergymagnetic.
Byanalyzethedataofthisexperiment,itshowsthatthepulsatingoftheweaktoadheartwould
makechangeafterstimulatedbymagnetic.Weakheartbeatstrengthened,thesinglepeakcurve
wouldbecomethetwopeakscurvewithatriawaveandventriclewaveafterthemagnetic
stimulation.Butthecyclingofrhythmicpulsatilecurveoftoaddoesn'tchange.
I.INTRODUTION
Alllifeformshavemagnetism.Allkindsofmagneticfieldwouldhavesomeeffectsonthe
configurationandactivitiesoflifeformsthatwhicheverenvironmentalmagnetic,additional
magneticorinsidemagneticoforganism.Thebiologiceffectsarerelatedtothecharacteristicsand
附录Ⅳ英文文献及翻译
2
theintensionofthemagneticfield,aswellasthespeciesandthetissuesofthelifeforms.
Theexperimentationshowedthatmagnetismstimulationinsomerangewouldcontrolthe
growthofrattumour,whatevertheyareinoroutthebody.Muchmoretheycaninducethecancer
cellsdead.30mTmagneticstimulationwouldincreasethecontentofNOintheliverandthe
kidney.Magneticalsocanimprovetheactivityofsomeenzymeandpromotetheregenerationof
nervetissue.Cellwouldincrease,theboneswouldbeconcrescence,thescarwouldbe
rehabilitate.Thebloodrheologyandbloodcellnumberbothofhumanandratwouldchange
obviously,DIthebloodmucositywouldbelow.
Heartisthemostimportantapparatusoflife.Itpulsatesdayandnight.Heartoncestop
pulsating,thelifefordanger.Numerousscholarpaysattentiontotheroleofmagneticfield.Butthey
juststudiedtheeffectsofmagneticstimulationoftheheartpacemaker.Theexperimentsabout
directeffectsofstimulateheartbymagneticisveryfew.
Thetoadsareourexperimentanimals.Westimulatedandnotedbythemagneticstimulation
equipmentandthenotedequipmentofpulsatilecurvemadebyourselves.Analyzetheresults.
II.STUFF
A.Experimentequipments:
①magneticstimulationequipment;(magneticintension8-10T,
impulsewidth150ms,maximalstimulationfrequency5Hz);②softwareofnotedpulsatilecurve
(madebyourselves);③cardiomusculartransducer;④Ringer.Sol;⑤Batrachiainstruments;⑥clip
offrogheart;⑦cottonthread;®burette.
B.Experimentanimals:
toads.
III.METHOD
A.Destroythebrainandthespinalcordofthetoadbystylet:
Penetrateintotheoccipital
apertureuprightwithstylet,destroyedthebrainupwards,takebackthestyletanddestroythespinal
downwards.Ifthelimboftoadwererelaxed,itshowedthatthebrainandspinalweredestroyed
completely.
B.Exposethetoadheart:
Makethetoadlyingonitsbackonthewindingcenter.Themagnetic
aspectisuprightthroughthetoadheart.Cuttheventralskinoftoad,snipthebreastbone,exposethe
ratheart.Nipthehearttipbyclipcarefully.Makethecottonthreadtiedwiththeclipoffroghearthe
linkedwiththecardiomusculartransducer.Donotmakethetoadheartleavethorax,oritwould
disturbtheexperimentresults.
C.Notedtheresult:
Connectthecardiomusculartransducerwiththecomputer.Takenotesthe
curveoftoadheartwithoutgivingthestimulateofmagneticfield
D.Afterthreeminutes,notedtheweakpulsatilecurve.
3
E.Makethemagneticintension10T,electricize10s.Stimulatethetoadheartandrecordthe
pulsatilecurve.
IV.RESULTS
Theabscissaofcardiacrhythmicpulsatilecurveistime,theordinateisconstrictionpower.
Takenotesforthepulsatilecurveoftoadheartthatexposedjust.Wecanknowtherhythmic
pulsatilecycleofthetoadheartis1.5sfromfig1whichshowthecardiacrhythmicpulsatilecurve
ofthetoadwhichwasexposedtheheartjustnow.Therearetwowavesineachcycle,oneisatria
wave,theotherisventriclewave.Theatriawaveis0.5sandtheventriclewaveis1.0s.The
constrictionpowerofatriaislessthanthatofventricle.Theamplitudeofconstrictionpowerof
ventricleisthe2timesoftheatria.
Fig.4.1.Itisrhythmicpulsatilecurveofthetoadwithoutmagneticstimulation.
Theconstrictionpoweroftoadheartwouldbecomeweakerafterthetoadheartwasexposed
forawhile.Atthesametime,atriumwaveandventriclewavecannotbealreadydistinguished.
Heartcontractingamplitudewerereducedobviously,donotgotothehalfoforiginalatriumwave.
Therhythmicpulsatilecycleofthetoadheartisstill1.5s.
Fig.4.2.Itistheweakpulsatilecurveoftoadwithoutmagneticstimulation.
Butwecandistinguishtheatriawaveandtheventriclewaveagainaftergivingthetoadhearta
magneticstimulationonfollowingpicture.Andtheamplitudeofventriclewavesismorethanthat
ofthesinglewave.Therhythmicpulsatilecycleofthetoadheartisstill1.5s.
Thereweresixtoadsasexperimentanimalinourexperiment.Afterexposingheartatime,the
rhythmicpulsatilecurveallbecamesinglepeakcurve.Stimulatethemwhenthesingleamplitude
4
was0.95.Notedthedataandanalyzethem.
Followingisthepulsatilecurveofthesixtoadsrecordedwhichwerestimulatedbymagnetic
field.
Fig.4.3.Itisthepulsatilecurveofthefisttoadwhichheartwasstimulatedbymagneticfield.
Fig.4.4.Itisthepulsatilecurveofthesecondtoadwhichheartwasstimulatedbymagneticfield.
Fig.4.5.Itisthepulsatilecurveofthethirdtoadwhichheartwasstimulatedbymagneticfield.
Fig.4.6.Itisthepulsatilecurveofthefourthtoadwhichheartwasstimulatedbymagneticfield.
5
Fig.4.7.Itisthepulsatilecurveofthefifthtoadwhichheartwasstimulatedbymagneticfield.
Fig.4.8.Itisthepulsatilecurveofthesixtoadswhichheartwasstimulatedbymagneticfield.
V.COMPARISIION
Recordventriclewaveamplitudeandatriumwaveamplitudeofthesixtoadsaftermagnetic
stimulation.
Table.5.1.From"Toad1"to"Toad6"expressedthesixtoadswhichwasstimulatedbymagneticfield.The"Toad0"
expressedthetoadwhichwasnotstimulatedbymagneticfield."Toad7"expressedthetoadwhichpulsatedweakly.
amplitudesofatriawaveamplitudesofventriclewave
Toad02.2752.34
Toad11.1401.170
Toad21.1201.129
Toad31.1651.18
Toad41.1201.128
Toad51.2141.230
Toad61.1511.169
Toad70.95
Expressthetoadwhichwasnotstimulatedbymagneticwith"Toad0",andexpressthetoad
whichpulsateweaklywith"Toad7".Makehistogramtocontrastbythesedata.Thefirsthistogram
wasmadebythedataofthepulsatileamplitudesofwhentoadwasnotgetsstimulateandpulsate
6
weakly,aswellasthepulsatileamplitudeofthefiststimulatedtoad.Aftermagneticstimulation,
amplitudesofatriawaveandventriclewavewerehigherthansinglewaveofweakheart.Butitis
morelowthantheamplitudesofheartwhenjustexposesobviously.
Fig.5.1.Thehistogramwasmakebytheamplitudesofthetoadexposedheartjustlyandthetoadwhichstimulated
bymagneticfield,thetoadwhichpulsateweakly.The"Toad0"expressedthetoadwhichwasnotstimulatedby
magneticfield.The"Toad1"expressedthefisttoadwhichwasstimulatedbymagneticfield.The"Toad7"
expressedthetoadwhichpulsatedweakly.
Makehistogramrespectivelywiththedataofamplitudeofeachtoadstimulatedbymagnetic
fieldandtheamplitudeofsinglewave.Makehistogramwiththedataofamplitudesofsixtoads
stimulatedbymagneticfield,andcomparethem.
Fig.5.2.Thehistogramwasmadebytheamplitudesofthefirsttoadwhichwasstimulatedbymagneticfieldand
thetoadwhichpulsateweakly.The"Toad1"expressedthefisttoadwhichwasstimulatedbymagneticfield.
The"Toad7"expressedthetoadwhichpulsatedweakly.
7
Fig.5.3.Thehistogramwasmadebytheamplitudesofthesecondtoadwhichwasstimulatedbymagneticfieldand
thetoadwhichpulsateweaklyThe"Toad2"expressedthesecondtoadwhichwasstimulatedbymagneticfield.The
"Toad7"expressedthetoadwhichpulsatedweakly.
Fig.5.4.Thehistogramwasmadebytheamplitudesofthethirdtoadwhichwasstimulatedbymagneticfieldand
thetoadwhichpulsateweakly.The"Toad3"expressedthethirdtoadwhichwasstimulatedbymagneticfield.
The"Toad7"expressedthetoadwhichpulsatedweakly.
Fig.5.5.Thehistogramwasmadebytheamplitudesofthefourthtoadwhichwasstimulatedbymagneticfieldand
thetoadwhichpulsateweakly.The"Toad4"expressedthefourthtoadwhichwasstimulatedbymagneticfield.The
"Toad7"expressedthetoadwhichpulsatedweakly.
8
Fig.5.6.Thehistogramwasmadebytheamplitudesofthefifthtoadwhichwasstimulatedbymagneticfieldand
thetoadwhichpulsateweakly.The"Toad5"expressedthefifthtoadwhichwasstimulatedbymagneticfield.The
"Toad7"expressedthetoadwhichpulsatedweakly.
Fig.5.7.Thehistogramwasmadebytheamplitudesofthewasstimulatedbymagneticfieldandthetoadwhich
puls,"Toad6"expressedthesixthtoadwhichwasstimulatedbyma"Toad7"expressedthetoadwhichpulsated
weakly.
Fig.5.8.Thehistogramwasmadebytheamplitudesofthewasstimulatedbymagneticfield.
9
Fig.5.9.Thehistogramwasmadebytheamplitudesofthewasstimulatedbymagneticfieldandthetoadwhich
pulsateweakly.
Thereisdiscrepancybetweenthepulsatileaeachtoadwhichstimulatedbymagneticfield.
Thisisdividualdiscrepancy,itisrelatedwiththestrongoftheexperimentanimals.Butifcompared
thesepulsatileamplitudesoftoadswhichstimulatedbymagneticfieldwithamplitudeofthetoad
whichpulsatedweaklyatthesametimeofdiscrepancyisverynotobvious.
VI.CONCLUSIONS
ThereareaPwaveandaQRSwanelectrocardiogram.Comparethepulsatilecurvewiththe
electrocardiogramtowecandiscoverthatthe